20V ac 2 Output Through Hole PCB Transformer, 12VA

  • RS Stock No. 504-511
  • Manufacturer RS PRO
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): PL
Product Details

230 Vac Primary Transformers

Fully shrouded bobbins
Extra pins for secure board mounting
100% electrical and flash tested
Tested in accordance with BS3535 and EN 60 742

//media.rs-online.com/t_line/L805502-01.gif

Approvals

8888

Standards

BS3535; EN 60 742

Open Frame - Laminated

PCB mounting mains transformers with a single 230Va.c. or twin 115Va.c. 50/60Hz primary winding. Independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options.

Double section metric bobbin constructionFull varnish impregnation

Specifications
Attribute Value
Secondary Voltage Rating 20V ac
Power Rating 12VA
Primary Voltage Rating 230V ac
Number of Outputs 2
Length 54mm
Width 45mm
Depth 41mm
Dimensions 54 x 45 x 41mm
Weight 400g
Mounting Type Through Hole
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
On back order for despatch 07/12/2020, delivery within 7 working days from despatch date.
Price (ex. GST) Each
$ 19.46
(exc. GST)
$ 21.41
(inc. GST)
units
Per unit
1 - 9
$19.46
10 - 24
$18.10
25 - 49
$17.21
50 - 99
$16.68
100 +
$16.23
Related Products
ABT7PDU series transformers This range of covered (up ...
Description:
ABT7PDU series transformers This range of covered (up to 320 VA) or uncovered (from 400 to 2500 VA) transformers features double windingSecondary winding coupling series or parallel with signalling LED and earthing by internal jumpers (up to 320 VA) or ...
Description:
Type UI 39 - 10 VA → 30 VA Secondary voltages are nominal load voltages on resistive loadsOnly the pins indicated on the wiring diagram "physically" exist. Standards IEC 742, VDE 0551, SEV 1003 Approvals UL 506. Secondary voltages are ...
Description:
Type EI 30 - 1 VA → 23 VA series 44000 transformers From Myyra, the 44000 Series of type EI transformers are professional safety transformers featuring an insulation of above 4000V. Inherently short circuit proof and comprising of non-flammable and ...
Transformers PCB Mount, Short Circuit Proof, AVB Series ...
Description:
Transformers PCB Mount, Short Circuit Proof, AVB Series Dual 115Vac. 50 to 60Hz primary Twin secondary windings for series or parallel connection AVB series are inherently short circuit proof compact design Vacuum epoxy resin moulded to UL94-V0 rating Double section ...