ABB 5 A Motor Load Monitor, 380 → 415 V, -10 → +60 °C

  • RS Stock No. 285-4607
  • Mfr. Part No. PAIR400L000
  • Manufacturer ABB
Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
Product Details

PAIR Motor Protection Relay

The PAIR module is designed for use with induction motors that require protection against both overload and underload conditions.

Overcurrent sensing with inverse time delay response
Sensitive underload protection by power factor measurement
Integral current transformer up to 32A
Current range can be extended with external current transformers
Adjustable start up and reset delays
Permanent memory of tripped status in the event of power loss
Indicator lamps for supply and tripped conditions
Reset can be automatic, manual and both local and remote
IP20 enclosure DIN rail mounting
Typical applications include protection against dry pumping for submersible pumps

Specifications
Attribute Value
Motor Protection System PAIR
Motor Protection Component Load Monitor
Sensing Type Current Transformer
Supply Voltage 380 → 415 V
Current Rating 5 A
Minimum Operating Temperature -10°C
Maximum Operating Temperature +60°C
1 In stock for delivery within 5 working day(s) (Global Stock)
Price (ex. GST) Each
$ 1,572.85
(exc. GST)
$ 1,730.13
(inc. GST)
units
Per unit
1 +
$1,572.85
Related Products
GV Panasonic Digital Keypad This is a digital ...
Description:
GV Panasonic Digital Keypad This is a digital display console that enables change of set parameters within the motors functionality Monitoring of rotational speed (actual speed) and load factor Displays trip details and trip history Motor parameter setting, initialisation and ...
The Omron K6CMseries indoor split is a motor ...
Description:
The Omron K6CMseries indoor split is a motor protection accessory It is compatible with the K6CM-VBM relay, motor condition monitoring device K6CM. The mounting type for this amplifier is a cable mount. • Monitor values of vibrations, temperature, insulation resistance ...
Quantifying the status of a three-phase induction motor ...
Description:
Quantifying the status of a three-phase induction motor and pump The alarm output threshold default is set. You can customize the value according to the site. As for comprehensive current diagnosis, the degradation can be detected comprehensively by combining each ...
Basic Unit SIMOCODE (SIRIUS Motor Management and Control ...
Description:
Basic Unit SIMOCODE (SIRIUS Motor Management and Control Devices) Pro C is a practicable and economical motor management systemSIMOCODE pro is a flexible, modular motor management system it optimizes the connection between I&C and motor system, increases plant availability and ...