TeSys GV2ME motor circuit breaker 4-6.3A

Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): FR
Product Details

Schneider Electric Motor Circuit Breakers GV2

Standards: BS5424 Part 1/IEC947, VDE 0660, NFC63 110.

Any downtime of machinery is detrimental to a business and its operations, Schneider Electrics GV2 series has been created and designed to act as an intermediary between machinery and devices, enabling the protection of important equipment in the event of an unforeseen incident. These circuit breakers can also be used for disconnection.

How do you select the right Motor Protection Circuit Breaker?

MPCBs are more critical now than ever. Most infrastructure now relies on a motor behind the scenes to power critical uninterruptible systems such as heating, ventilation, cooling all of which we take for granted. These systems are vital in ensuring business productivity and therefore must be protected against overcurrent's, thermal overloads and much more.

To select the right MPCB, consider the systems you and your business rely upon. Checking the features and benefits of each MPCB will prove invaluable when deciding what critical infrastructure you wish to protect.

Approvals

UL, CSA

Schneider Electric Motor Protection Circuit Breaker - GV2ME10

• Significantly reduces downtime of machinery which allows operations to operate smoothly and safe
• Forms part of the TeSys range of products, formally known as the TeSys GV2
• 3 poles
• AC network type
• The network frequency is 50/60 Hz which conforms to IEC 60947-4-1
• Option to mount by clips or screws with a rail
• Users can choose if they would like to mount the circuit breaker horizontally or vertical
• Pushbutton control type
• This motor protection circuit breaker features an ingress protection rating of IP20, this means that it is protected against solid objects that are over 12.5mm such as hands and large tools. This IP rating also means that the circuit breaker has no protection against liquid
• Mechanically durable for up to 1000000 cycles
• Electrical durability up to 1000000 cycles for AC-3 at 440 V
• Dimensions - H89mm x W45mm x D78.2mm
• Motor power kW - 4 kW at 690 V AC 50/60 Hz, 3 kW at 500 V AC 50/60 Hz and 2.2 kW at 400/415 V AC 50/60 Hz

Specifications
Attribute Value
Current Range 4 → 6.3 A
Number of Poles 3P
Range TeSys
Breaking Capacity 3 kA
Terminal Type Screw
Voltage Rating 690 V
Reset Method Manual
Length 89mm
Width 44.5mm
Depth 78.2mm
Dimensions 89 x 44.5 x 78.2 mm
Series GV2M
For Use With Motor Protection
177 In stock for delivery within 5 working day(s) (Global Stock)
Price (ex. GST) Each
$ 347.65
(exc. GST)
$ 382.41
(inc. GST)
units
Per unit
1 - 2
$347.65
3 - 4
$317.23
5 +
$295.02
Related Products
The ABB 110-125V ac/dc motor operator is used ...
Description:
The ABB 110-125V ac/dc motor operator is used for power circuit breaker It is suitable for product class SACE Tmax XT. Standards IEC 60947-2Configuration type can be loose or configurable.
MICO Classic Circuit Breaker The MICO Classic range ...
Description:
MICO Classic Circuit Breaker The MICO Classic range by Murr Elektronik are an intelligent power distribution system for 24 V dc systems MICO monitors currents and indicates via the LED when the maximum load is being approached, the current range ...
Circuit breaker 3VA2 IEC frame 250 breaking capacity ...
Description:
Circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 4-pole, LI, In=250A overload protection Ir=100A..250A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit.
Motor Protection Switches - XL-2000-01 Overload protection compensated ...
Description:
Motor Protection Switches - XL-2000-01 Overload protection compensated -5 to +40°CLockable in 'OFF' position Short circuit protection, therefore, no back-up fuse protection is required where the prospective fault level is less than the breaking capacity of the unit Expected life ...