105W Light Transformer, 230V ac, 11.5V ac

  • RS Stock No. 158-7227
  • Mfr. Part No. HIT 105
  • Manufacturer Block
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

Halogen transformer, HIT series

Adjusting the voltage to the optimum setting for the transformer extends the service life of the halogen bulbs
Input and output-end screw connection terminals with strain relief
During normal mains overvoltage, the nominal voltage of the halogen bulbs is not exceeded
Integrated fuse protection and temperature limiter serve as protection in the event of short-circuit and overload
Easy to use, even where the fire behaviour of the building material (wood, furniture, internal ceilings) is unknown

Short-circuit proof safety transformers in cast resin, fully encapsulated to supply 12 V halogen bulbs

Standards

VDE 0570 part 2-6, IEC 61558-2-6, DIN EN 61558-2-6

//media.rs-online.com/t_line/LD158721-03.gif

Approvals

VDE 0551

Standards

EN61558

Specifications
Attribute Value
Primary Voltage Rating 230V ac
Secondary Voltage Rating 11.5V ac
Power Rating 105W
Dimensions 166 x 76 x 77mm
Length 166mm
Width 76mm
Depth 77mm
Maximum Temperature +40°C
Weight 2kg
Type Isolation
10 In stock for delivery within 5 working day(s) (Global Stock)
Price (ex. GST) Each
$ 110.99
(exc. GST)
$ 122.09
(inc. GST)
units
Per unit
1 - 9
$110.99
10 - 24
$107.78
25 - 49
$104.45
50 - 99
$103.13
100 +
$101.35
Related Products
Chassis Mount Frame 75VA to 200VA The two ...
Description:
Chassis Mount Frame 75VA to 200VA The two independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options Optional terminal shrouds for 75VA and 100VA. The two independent secondary ...
Control Panel Primary 230/ 400Vac with +15Vac Tap ...
Description:
Control Panel Primary 230/ 400Vac with +15Vac Tap High quality safety and isolating transformers designed for use in control circuits and general applications Low loss noise laminations Dual standard primary winding 230 / 400Vac with +15V tap for input flexibility ...
Control Panel Primary 230/400Vac with +15Vac Tap High ...
Description:
Control Panel Primary 230/400Vac with +15Vac Tap High quality safety and isolating transformers designed for use in control circuits and general applications Low loss noise laminations Dual standard primary winding 230 / 400Vac with +15V tap for input flexibility Dual ...
RS Pro Single Phase DIN Rail Isolation Transformer ...
Description: