Eaton 4 kW Automatic 3P DOL Starter, 400 V ac, IP65

  • RS Stock No. 528-7369
  • Mfr. Part No. 118523 & XDP4/I(400V50HZ,440V60HZ)
  • Manufacturer Eaton
Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): GB
Product Details

EATON XDP DOL Starter Series with Isolator

Providing reliability and long operating life, these 'direct-on-line' starters are totally insulated with IP65 protection. Capable of high numbers of operations, these starters are constructed from standard components meaning they are very easy to maintain. Fitted with AC-3 rated triple pole contactor, AC-3 rated triple pole switch disconnector and on and off pushbuttons, these devices also allow for 3 padlocks for additional safety.

All starters in this range are wired to accept EATON overload relays for overload protection, also available from RS components to be purchased separately.
4 & 5.5kW models = H200 x W120 x D160mm, 7.5 & 11kW models = H240 x W160 x D160mm

Features and Benefits:

• Fitted with metric knockouts
• Easy maintenance
• Complies with IEE regulations
• 16th edition on isolation and switching
• Glass fibre reinforced polycarbonate casing

Applications:

Used for starting 3 phase induction motors, direct on line starters are regularly used in industrial applications such as conveyor belts, compressors and small water pumps.

What is the difference between dol and star delta starters?

Both devices are used to start induction motors however, where partial voltage is applied to each winding of a star delta starter, a DOL has 100% voltage applied. This also applies to the current, a star delta uses one-third of the starting current that a DOL does. Direct on line starters are the most common and simplest starting method, within a motor start-up they also provides the lowest temperature rise. Star delta starters allow for starting the motor at a lower voltage, making them suitable for high inertias.

Note

FLC figures quoted are maximum, other overload ratings can be used dependant on FLC rating.

Standards

IEC/EN 60529, DIN 43660, EN 50262

Specifications
Attribute Value
Power Rating 4 kW
Motor Starter Type DOL
Voltage Rating 400 V ac
IP Rating IP65
Number of Poles 3P
Motor Starter Functionality Automatic
Additional Features Disconnect Switch Included
Overall Length 200mm
Enclosure Yes
Overall Width 120mm
Overall Depth 160mm
Series XDP
Stock check temporarily unavailable - call for stock availability
Price (ex. GST) Each
$ 379.15
(exc. GST)
$ 417.07
(inc. GST)
units
Per unit
1 +
$379.15
Related Products
Standard Control Units Ideal to satisfy the basic ...
Description:
Standard Control Units Ideal to satisfy the basic protection requirements for motor starters; thermal overload and short-circuit Protection against overloads and short-circuits Protection against phase failure and phase imbalance Protection against insulation breaks (equipment protection only)Manual reset Class 10 ...
Direct starters for motor control, unidirectional Direct starters ...
Description:
Direct starters for motor control, unidirectional Direct starters for motor control used in machines subject to application of Machine Directive 89/392/EECOne-directional starters with push-button isolation control.Short circuit and overload protection.Pre-wired casing ready for use, just needs power and ...
Te Sys starter in box Unidirectional direct starter ...
Description:
Te Sys starter in box Unidirectional direct starter for motor control with 10 x 38mm fuseholder switch-disconnector to 11kWExcept ref. LE4K35 with14 x 51mm fuseholder switch-disconnector, unidirectional to 15kW.Attachment surface different compared to the old product (larger product).Box with switch-disconnector, ...
Non Reversing DOL Starter These motor starters are ...
Description:
Non Reversing DOL Starter These motor starters are available in a selection of formats. All have removable steel base plates for rigidity when mounting to an uneven surface and ease of earthing and wiring and an impact resistant polycarbonate front ...