ABB Manual 3P Motor Protection Circuit Breaker, 690 V ac, 1, 3 Phase, IP20

  • RS Stock No. 445-0364
  • Mfr. Part No. MS116-4.0
  • Manufacturer ABB
Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): DE
Product Details

Starters

Covers motors up to 16A (7.5kW)
Local isolator
Protects against overloads, short circuits, phase failure and faults in cabling or wiring
These Motor Starters can be used in conjunction with ABB Contactors, stock no. 445-0897 typically
Accessories available from auxiliary/signal contacts to under voltage releases. Using an adaptor, motor starter combinations can be easily formed utilising contactors from ABB's mini and A series range; see typically 445-0897 and 445-0825

Technical Specification
Rated Current 0.1 to 1.6A (11 ranges)
Width 45mm
Rated operating voltage 690Vac /440Vdc
Tripping Class 10/10A
Rated short circuit breaking capacity Ics at 400 Vac, 16A 10kA
Mechanical lifetime 100.000 switches
Line Drawing Key
PSI Phase busses
S1-M1 Infeed block, flat
S1-M2 Infeed block, high
SK1 Signal contacts for lateral mounting
HK1 Auxiliary contacts for lateral mounting
HKF-11 Auxiliary contacts for front mounting
UA1 Undervoltage release
SA1 Locking device
BEA7/16 Mounting adaptor for mini contactors
BEA16/116 Mounting adaptor for A9-A16 contactors

Standards

IEC 60 947-1/IEC 60 947-2/EN60 P47-1/EN60 (47-2)

Approvals

UL, CSA

//media.rs-online.com/t_line/LF445029-02.gif
Specifications
Attribute Value
Motor Starter Type DOL
Voltage Rating 690 V ac
IP Rating IP20
Phase 1, 3
Number of Poles 3P
Motor Starter Functionality Manual
Overall Length 90mm
Enclosure Yes
Overall Width 45mm
Overall Depth 80.1mm
Series MS116
4 : Next working day (AU stock)
13 : 5 working days (Global stock)
Price (ex. GST) Each
$ 116.49
(exc. GST)
$ 128.14
(inc. GST)
units
Per unit
1 +
$116.49
Related Products
The ABB MS132 series of manual motor starters ...
Description:
The ABB MS132 series of manual motor starters are compact highly reliable devices used to manually switch on and off motors. The MS132 series protects the motors reliably, without the need for a fuse, from short-circuits, overload and phase failures. ...
Maximum rated current 100A (45kW @ 400V a.c.)Rated ...
Description:
Maximum rated current 100A (45kW @ 400V a.c.)Rated operational voltage: 690VShort-circuit proof to 50kA @ 400V a.c.Maximum switching frequency; 15 operations/hourMechanical life; 105 operationsAmbient temperature range; –20 to +60 ° CLong term stabilityManual resetLockable in off position.
This Siemens 3RV1021-4BA10 Manual Motor Starter is rated ...
Description:
This Siemens 3RV1021-4BA10 Manual Motor Starter is rated as 20A and has a thermal overload release range of 14 to 20A. Maximum rated current 100A (45kW @ 400V a.c.)Rated operational voltage: 690VShort-circuit proof to 50kA @ 400V a.c.Maximum switching frequency; ...