Schneider Electric 400VA Panel Mount Transformer, 215V ac, 230V ac, 245V ac, 385V ac, 400V ac, 415V ac Primary 2 x, 24V

Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): CZ
Product Details

ABT7PDU series transformers

This range of covered (up to 320 VA) or uncovered (from 400 to 2500 VA) transformers features double winding.
Secondary winding coupling series or parallel with signalling LED and earthing by internal jumpers (up to 320 VA) or plug-in jumpers (from 400 to 2500 VA).
Panel mounting using 4 screws.

Approvals

CURus, ENEC

Laminated Frame 230Vac Primary 75VA to 200VA (Multi Tapped)

Chassis mounting frame construction low voltage mains transformers with a single 230Vac 50/60Hz primary winding.

Double section bobbin construction
Fully shrouded bobbins
Full varnish impregnation
Multi-hole frame fixing
Solder tag terminations
100% electrical and flash tested
Tested in accordance with BS3535 and EN 60 742

Specifications
Attribute Value
Primary Voltage Rating 215V ac, 230V ac, 245V ac, 385V ac, 400V ac, 415V ac
Secondary Voltage Rating 24V ac
Power Rating 400VA
Mounting Type Chassis
Number of Outputs 2
Length 151mm
Width 160mm
Depth 113mm
Dimensions 151 x 160 x 113mm
Minimum Operating Frequency 47Hz
Maximum Operating Frequency 63Hz
Minimum Temperature -20°C
Maximum Temperature +40°C
Weight 7.4kg
On back order for despatch 04/11/2020, delivery within 7 working days from despatch date.
Price (ex. GST) Each
$ 526.99
(exc. GST)
$ 579.69
(inc. GST)
units
Per unit
1 - 9
$526.99
10 - 24
$513.78
25 - 49
$486.76
50 - 99
$472.43
100 +
$460.61
Related Products
Te Sys T Series - Current Transformers Professional ...
Description:
Te Sys T Series - Current Transformers Professional range of Schneider Electric motor controller external current transformers from the Te Sys T series The current transformers are available in various current ratings. Professional range of Schneider Electric motor controller external ...
Control transformers, 1-phase, 4AM Series Use as power, ...
Description:
Control transformers, 1-phase, 4AM Series Use as power, safety or displacement transformers in accordance with the applicable EN norm High short-term performance Low switch-on power (switch-on rush)Protect against short circuits and overloading with motor protection switches on main side Electrically ...
Control Panel Primary 690Vac (63/2500VA) Low inrush current ...
Description:
Control Panel Primary 690Vac (63/2500VA) Low inrush current control, safety isolating and isolating transformer Screw type terminals, fitted with screw mounting brackets Compact design with ±20V tappings on the primary winding For use up to +40°C ambient maximum Low inrush ...
Description:
Type UI 30 - 3 VA → 10 VA Secondary voltages are nominal load voltages on resistive loadsOnly the pins indicated on the wiring diagram "physically" exist. Standards IEC 742, VDE 0551, SEV 1003 Approvals UL 506. Secondary voltages are ...