HOBUT DIN Rail Mounted Circuit Transformer, -30 → +85 °C, 300:5

  • RS Stock No. 331-389
  • Mfr. Part No. CT143M300/5-5/1-001
  • Manufacturer HOBUT
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): GB
Product Details

Compact Busbar/Base Mounting Current Transformers - Series 14

A range of compact moulded case current transformers suitable for primary currents from 25A to 500A with built-in sealable terminal covers. For transforming various primary currents into 5A standard secondary current using 20mm or 30mm busbars or 24mm cables.

DIN rail mounting clip supplied
Built-in sealable terminal covers
Mounting feet and busbar screws supplied
Narrow width
Dimensions: H70 x W49 x D30mm
Conforms to IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Rated system voltage: 0.72/3kV
Ambient temperature range: -30 to 85°C
Continuous current: 1.2 x rated current

Current Transformers

Specifications
Attribute Value
Current Ratio 300:5
Inner Diameter 24mm
Transformer Type DIN Rail Mounted
Overall Height 70mm
Overall Width 49mm
Overall Depth 45mm
Minimum Temperature -30°C
Maximum Temperature +85°C
On back order for despatch 03/07/2020, delivery within 5 working days from despatch date.
Price (ex. GST) Each
$ 25.16
(exc. GST)
$ 27.68
(inc. GST)
units
Per unit
1 - 4
$25.16
5 - 9
$24.72
10 +
$24.26
Related Products
Moulded Case Current Transformer – 24mm Aperture Power ...
Description:
Moulded Case Current Transformer – 24mm Aperture Power consumption 25VA, 50/60Hz Accuracy class 120 or 30mm busbar mounting Suitable for circular conductors 24 aperture Maximum aperture for bar conductors 30x10mm (type 6)Operating temperature range –30 to +85°CSecondary terminals M5 studs ...
Set consisting of a 1 A measuring transducer ...
Description:
Set consisting of a 1 A measuring transducer and a Rogowski coil with signal line Length of Rogowski coil: 300 mm, diameter: 95 mm. Length of signal line: 10 m. The Rogowski coil measures the AC current of busbars and ...
Set consisting of a 4-way signal conditioner with ...
Description:
Set consisting of a 4-way signal conditioner with push-in connection technology and a Rogowski coil 450 mm in length/140 mm in diameter for AC current measurement on busbars and power lines The signal conditioner outputs 8 different standard signals on ...
Pin-winding increases the primary current of the current ...
Description:
Pin-winding increases the primary current of the current transformer Consequently, window-type current transformers Can also be used for low primary currents.