Aim I-prober 520 PCB Track “Positional” Current Probe

The I-Prober 520 is a unique current measurement device. Measurement of current normally requires it to be passed through a closed magnetic loop, typically using a split clamp device. Whereas this is suitable for individual wires, it is of no use for measuring current in PCB tracks. The I-Prober 520 uses positional H-field measurement. By placing the insulated tip of the probe onto a PCB track, the current flowing in the track can be observed and measured. The I-Prober 520 is supplied with a clip-on toroid assembly which converts it into a closed magnetic circuit probe for measuring current within a wire.

Current measurement from isolated probing of conductor
Patented Micro Fluxgate Magnetometer technology
Wide dynamic range of 10mA to 20A peak to peak
Wide bandwidth of DC to 5MHz
Low noise equivalent to <6mA rms
Designed to meet safety requirements to 300V Cat II
Suitable for connection to any 1M input oscilloscope
High accuracy general purpose H-field probe
Convertible into ’closed magnetic circuit’ current probe

Supplied with

Control box, power supply, toroid assembly, fitted carrying case, operator's manual

Aim-TTI I-prober 520 Positional Current Probe

The Aim-TTI I-prober 520 positional current probe has a current rating of 20A. It can observe and measure currents in PCB tracks and other conductors where conventional current probes cannot be used. This includes captive wires into components, the legs of integrated circuits, and PCB ground planes. Conventionally, you can only measure the current by either breaking the circuit to insert a shunt resistor or by surrounding the conductor by a loop of magnetic material as in a standard current probe. It enables currents, from DC up to 5MHz, and lets you observe and measure simply by placing its insulated tip onto the conductor.
Supplied with:
Control box, power supply, toroid assembly, fitted carrying case, and an operator's manual

Features and Benefits

• Current measurement from isolated probing of conductor
• Patented micro fluxgate magnetometer technology
• Wide bandwidth of DC to 5MHz
• Low noise equivalent to less than 6mA rms
• Suitable for connection to any 1M input oscilloscope
• High accuracy general purpose H-field probe
• Convertible into closed magnetic circuit current probe

Applications

• High voltage conductors
• High-temperature areas
• Confined and difficult to access spaces

Certifications

• 300V Cat II safety rated
• EN61326

Specifications
Attribute Value
Current 20A
Probe Type AC/DC
Minimum Bandwidth 0Hz
Maximum Bandwidth 5000kHz
Safety Category CAT II 300 V
Safety Category Level CAT II
Model Number p I-prober 520
Best Accuracy ±3 %
Safety Category Voltage 300V
Bandwidth DC to 2 Hz, DC to 5 MHz, DC to 500 kHz
6 In stock for delivery within 5 working day(s)
Price (ex. GST) Each
$ 1,182.30
(exc. GST)
$ 1,300.53
(inc. GST)
units
Per unit
1 +
$1,182.30
Related Products
Dual range a.c. current clamp nominal measuring ranges ...
Description:
Dual range a.c. current clamp nominal measuring ranges 0.1A to 20A a.c. and 0.5A to 200A a.c.Safe, non intrusive current measurement40Hz to 10kHz bandwidthErgonomic jaw design for measurement where access is difficult and allows 'hooking' onto the cableMax. conductor size ...
The i30 may be used in conjunction with ...
Description:
The i30 may be used in conjunction with bench and portable oscilloscopes for accurate non-intrusive ac & dc current measurement.,Applications include: inverters, switch mode power supplies, industrial controllers, automotive leakage currents and other applications requiring accurate isolated current measurement. ...
Suitable for use with oscilloscopes, recorders and data ...
Description:
Suitable for use with oscilloscopes, recorders and data loggers a.c. coupled output (no d.c. offset) Voltage output of 3V full scale for each range Fits around conductors up to 160mm diameter Extended battery life and external power supply input Meets ...
Various bandwidths: DC to 50 MHz, 100 kHzDC ...
Description:
Various bandwidths: DC to 50 MHz, 100 kHzDC and AC measurementsSuperior accuracy and high signal to-noise ratioLow circuit insertion lossBattery powered with BNC connector or oscilloscope powered AutoProbe interface.