RS PRO 12VA 2 Output Chassis Mounting Transformer, 9V ac

  • RS Stock No. 503-978
  • Manufacturer RS PRO
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): PL
Product Details

Chassis Mount Clamp & Frame Construction 115/230Vac Primary Transformer

Double section bobbin construction
Fully shrouded bobbins
Full varnish impregnation
Two hole fixing wrap-over clamps 6VA to 50VA
Multi-hole frame fixing 100VA
Solder tag terminations
Optional terminal shrouds
100% electrical and flash tested
Tested in accordance with BS3535 and EN 60 742

Note

Suitable transformer shrouds: 6VA = 503-912 ; 12 & 20VA = 504-004 ; 50, 75 & 100VA = 503-928

Approvals

8888

Standards

BS3535; EN 60 742

Open Laminated Clamp & Frame 115-230Vac Primary 6VA to 100VA

Chassis mounting mains transformers with twin 115Va.c. 50/60Hz primary windings which may be connected in series for 230V or parallel for 115V operation. The two independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options.

Specifications
Attribute Value
Primary Voltage Rating 115V ac, 230V ac
Secondary Voltage Rating 9V ac
Power Rating 12VA
Number of Outputs 2
Mounting Type Clamp Mount
Length 59mm
Width 50mm
Depth 50mm
Dimensions 59 x 50 x 50mm
Fixing Hole Diameter 4.7 x 8.7mm
Weight 400g
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
5 : Next working day (AU stock)
8 : 7 working days (Global stock)
Price (ex. GST) Each
$ 25.37
(exc. GST)
$ 27.91
(inc. GST)
units
Per unit
1 - 9
$25.37
10 - 24
$24.95
25 - 49
$23.83
50 - 99
$22.98
100 +
$22.33
Related Products
Cable Primary Current Sense Transformer 50/60Hz Current Transformers ...
Description:
Cable Primary Current Sense Transformer 50/60Hz Current Transformers PCB mounting Applications include, Sensing Overload Current, Ground fault detection, Metering and Analog to Digital Circuits 50/60Hz Current Transformers PCB mounting Applications include, Sensing Overload Current, Ground fault detection, ...
Control transformers, 1-phase, 4AM Series Use as power, ...
Description:
Control transformers, 1-phase, 4AM Series Use as power, safety or displacement transformers in accordance with the applicable EN norm High short-term performance Low switch-on power (switch-on rush)Protect against short circuits and overloading with motor protection switches on main side Electrically ...
Description:
Type UI 39 - 10 VA → 30 VA Secondary voltages are nominal load voltages on resistive loadsOnly the pins indicated on the wiring diagram "physically" exist. Standards IEC 742, VDE 0551, SEV 1003 Approvals UL 506. Secondary voltages are ...
Description:
Type EI 30 - 1 VA → 23 VA series 44000 transformers From Myyra, the 44000 Series of type EI transformers are professional safety transformers featuring an insulation of above 4000V. Inherently short circuit proof and comprising of non-flammable and ...