Safety Contactors

Safety contactors are a type of safety relay, designed to ensure that if there is a fault either externally or within a device, the circuit will remain safe. They monitor functions in the circuit and react to faults, often by stopping or preventing the movement of parts.

How do safety contactors work?

Safety contactors are devices used for risk reduction in industrial settings. They work by switching the power in an electronic circuit, usually by breaking the circuit with electrical contacts. When a fault is detected, they will isolate the function they are monitoring, preventing it from continuing to work.

Each safety contactor measures a specific function, and there is usually a whole network of interconnected safety contactors working together to minimise risk.

Types of safety contactors

Safety contacts can vary by design in a number of different ways. This includes the number of contacts, their current and voltage rating, and their dimensions, which can vary quite significantly.


...
Read more Read less

Filters

Viewing 1 - 20 of 68 products
Results per page
Description Price Number of Contacts Range Pole and Throw Configuration Series Normal State Configuration Number Of Auxiliary Contacts Auxiliary Contacts Contact Current Rating Contact Voltage Rating Coil Voltage Length Width Depth Minimum Operating Temperature
RS Stock No. 766-1936
Mfr. Part No.3TK2852-1BB40
BrandSiemens
$557.69
Each
units
- SIRIUS 6P 3TK28 6NO/NC - - 10 A 600 V ac 24 V dc 132mm 90mm 146mm -25°C
RS Stock No. 766-1891
Mfr. Part No.3TK2850-1AJ20
BrandSiemens
$510.34
Each
units
- SIRIUS 3P 3TK28 3NO - - 10 A 600 V ac 115 V ac 132mm 90mm 108mm -
RS Stock No. 175-3231
Mfr. Part No.1SBL367082R1122
BrandABB Jokab
$426.70
Each
units
3 - 3P AFS 3NO 4 2NO/2NC 100 A 600 V ac 20 → 60 V dc, 24 → 60 V @ 50/60 Hz 55mm 144mm 119.5mm -40 °C, -25 °C
RS Stock No. 187-5331
Mfr. Part No.191701
BrandEaton
$93.40
Each
units
3 - 3P DILMS 3NO 5 2NO/3NC 7 A 400 V 110 V ac @ 50 Hz, 120 V ac @ 60 Hz 45mm 117mm 68mm -25°C
RS Stock No. 187-5338
Mfr. Part No.191741
BrandEaton
$100.16
Each
units
3 - 3P DILMS 3NO 5 2NO/3NC 9 A 400 V 230 V ac @ 50 Hz, 240 V ac @ 60 Hz 45mm 117mm 68mm -25°C
RS Stock No. 175-3232
Mfr. Part No.1SBL367082R1322
BrandABB Jokab
$417.53
Each
units
3 - 3P AFS 3NO 4 2NO/2NC 100 A 600 V ac 100 → 250 V dc, 100 → 250 V @ 50/60 Hz 55mm 144mm 119.5mm -40 °C, -25 °C
RS Stock No. 187-5336
Mfr. Part No.191721
BrandEaton
$149.98
Each
units
3 - 3P DILMS 3NO 5 2NO/3NC 7 A 400 V 24 V dc 45mm 117mm 68mm -25°C
RS Stock No. 187-5356
Mfr. Part No.191745
BrandEaton
$243.65
Each
units
3 - 3P DILMS 3NO 5 2NO/3NC 32 A 400 V 230 V ac @ 50 Hz, 240 V ac @ 60 Hz 56mm 138mm 85mm -25°C
RS Stock No. 175-3215
Mfr. Part No.1SBL237082R1322
BrandABB Jokab
$171.13
Each
units
3 - 3P AFS 3NO 4 2NO/2NC 45 A 600 V ac 100 → 250 V dc, 100 → 250 V @ 50/60 Hz 45mm 119.5mm 80mm -40 °C, -25 °C
RS Stock No. 187-5339
Mfr. Part No.191762
BrandEaton
$129.85
Each
units
3 - 3P DILMS 3NO 5 2NO/3NC 9 A 400 V 24 V dc 45mm 117mm 68mm -25°C
RS Stock No. 175-3233
Mfr. Part No.1SBL387082R1122
BrandABB Jokab
$495.53
Each
units
3 - 3P AFS 3NO 4 2NO/2NC 105 A 600 V ac 20 → 60 V dc, 24 → 60 V @ 50/60 Hz 55mm 144mm 119.5mm -40 °C, -25 °C
RS Stock No. 187-5332
Mfr. Part No.191740
BrandEaton
$93.40
Each
units
3 - 3P DILMS 3NO 5 2NO/3NC 7 A 400 V 230 V ac @ 50 Hz, 240 V ac @ 60 Hz 45mm 117mm 68mm -25°C
RS Stock No. 187-5337
Mfr. Part No.191702
BrandEaton
$100.16
Each
units
3 - 3P DILMS 3NO 5 2NO/3NC 9 A 400 V 110 V ac @ 50 Hz, 120 V ac @ 60 Hz 45mm 117mm 68mm -25°C
RS Stock No. 187-5326
Mfr. Part No.191739
BrandEaton
$91.59
Each
units
- - - DILAS - 8 4NO/4NC 4 A 415 V 230 V ac @ 50 Hz, 240 V ac @ 60 Hz 45mm 117mm 68mm -25°C
RS Stock No. 175-3201
Mfr. Part No.1SBL137082R1122
BrandABB Jokab
$151.43
Each
units
3 - 3P AFS 3NO 4 2NO/2NC 25 A 600 V ac 20 → 60 V dc, 24 → 60 V @ 50/60 Hz 45mm 110.5mm 80mm -40 °C, -25 °C
RS Stock No. 187-5328
Mfr. Part No.191732
BrandEaton
$142.35
Each
units
- - - DILAS - 8 4NO/4NC 4 A 415 V 110 V ac @ 50 Hz, 120 V ac @ 60 Hz 45mm 117mm 68mm -25°C
RS Stock No. 175-3205
Mfr. Part No.1SBL156082R3022
BrandABB Jokab
$173.43
Each
units
3 - 3P AFS 3NO 4 2NO/2NC 28 A 600 V ac 24 V dc 45mm 110.5mm 80mm -40 °C, -25 °C
RS Stock No. 187-5358
Mfr. Part No.191738
BrandEaton
$333.56
Each
units
3 - 3P DILMS 3NO 5 2NO/3NC 32 A 400 V 110 V ac @ 50 Hz, 120 V ac @ 60 Hz 56mm 138mm 85mm -25°C
RS Stock No. 187-5341
Mfr. Part No.191755
BrandEaton
$143.56
Each
units
3 - 3P DILMS 3NO 5 2NO/3NC 9 A 400 V 230 V ac @ 50 Hz, 240 V ac @ 60 Hz 45mm 117mm 68mm -25°C
RS Stock No. 187-5333
Mfr. Part No.191761
BrandEaton
$105.13
Each
units
3 - 3P DILMS 3NO 5 2NO/3NC 7 A 400 V 24 V dc 45mm 117mm 68mm -25°C
Related Products
AFS09Z .. AFS38Z contactors are designed for machine ...
Description:
AFS09Z .. AFS38Z contactors are designed for machine safety applications. They are delivered with fixed front-mounted auxiliary contact blocks making them ideal for monitoring and controlling circuits. Mechanically linked and mirror contacts make your system safer. - control circuit with ...
AFS40 .. AFS96 contactors are designed for machine ...
Description:
AFS40 .. AFS96 contactors are designed for machine safety applications. They are delivered with fixed front-mounted auxiliary contact blocks making them ideal for monitoring and controlling circuits. Mechanically linked and mirror contacts make your system safer. - control circuit with ...
The SIRIUS 3TK28 5 safety relay combines solid-state ...
Description:
The SIRIUS 3TK28 5 safety relay combines solid-state safety functionality and two redundant contacting auxiliary contactors These safety relays/contactors are supplied ready assembled, wired, tested and certified as a single unit. Available with spring-loaded or screw terminals. Enabling circuits, ...
Relay module with driven contacts, Nominal input voltage: ...
Description:
Relay module with driven contacts, Nominal input voltage: 24 VDC, 2 changeover contacts, Limiting continuous current: 8 A, Red status indicator, Module width: 15 mm Reinforced insulation between coil and contactsA separator plate (e.g., 209-191) must be used for voltages ...